AC Resistive Load Bank
-
Price:
Negotiable
- minimum:
- Total supply:
-
Delivery term:
The date of payment from buyers deliver within days
-
seat:
Beijing
-
Validity to:
Long-term effective
-
Last update:
2022-02-24 06:24
-
Browse the number:
440
+
- Contactaixin:
rataloadbank(Mr.)
- Email: telephone: phone:
-
Arrea:
Beijing
Address:East Section of Hongyu Road, Jinshan Industrial Park, Luojiang District, Deyang City, Sichuan Province
-
Website:
http://www.cnloadbank.com/ http://rataloadbank.sh-dongyun.com/
+
PRODUCT OVERVIEW
R103kw / 400V / 50Hz load bank is an ac resistive load bank developed and produced by our company. The load bank can carry out 25% unbalance test with power factor of 1.0. It adopts three-phase four wire system and can carry out dummy load test for generator set, transformer, ups and other power supply equipment.
PRODUCT PICTURE
APPLICATION SCENARIO
PARTIAL PARAMETERS
Note: all parameters are for reference only and can be customized | |
Product name |
ac resistive load bank |
Specifications |
R500kW/400V/690V/50Hz |
Formation |
One load bank(Including dry resistance load, electrical control components, measurement and control system) |
Load step |
According to customer needs |
Load connection |
Copper bar |
Resistor |
Each resistance element: insulation impedance DC1000V/100MΩ above Withstand voltage ac 2000v for 5min Resistance error of each resistance tube:±3% |
Load control |
Local manual control, local automatic control or remote automatic control can be selected |
Loading accuracy |
Less than or equal to 3% |
Three phase balance |
Unbalance degree less than or equal to 3% |
Minimum step |
1kW |
Working mode |
Continuous work |
Load protection |
Short circuit, overcurrent, high temperature, fan fault protection |
External power |
TN-C,380V/50Hz |
Cooling mode |
Forced air cooling, side air outlet or top air outlet |
Insulation class |
F |
Measurement accuracy |
The display accuracy is 0.5,the sampling accuracy is 0.2 |
Electrical parameter display |
Three phase voltage, three-phase current, frequency, power, etc |
Load expansion |
Parallel expansion of multiple load containers |
Standard |
Meet international standard, ship standard, military standard and telecommunication standard |
Color |
Customized |
Ambient temperature |
-20℃ to 50℃ |
Humidity |
Up to 100% |
Altitude |
Up to 2500m |
Atmospheric pressure |
86 to 106kPa |
MORE SPECIFICATIONS
Note: all parameters are for reference only and can be customized | ||||
Power(kW) |
Voltage(kV) |
Frequency(Hz) |
Size(mm,L*W*H) |
Weight(Kg) |
Low voltage | ||||
100 |
0.4 |
50 |
1100*900*1000 |
320 |
200 |
0.4 |
50 |
1350*1100*1100 |
450 |
300 |
0.4 |
50 |
1500*1200*1200 |
650 |
400 |
0.4 |
50 |
1700*1500*1500 |
830 |
500 |
0.4 |
50 |
1700*1600*1600 |
950 |
600 |
0.4 |
50 |
1800*1600*1600 |
1150 |
800 |
0.4 |
50 |
1900*1800*1700 |
1900 |
1000 |
0.4 |
50 |
2300*1700*2100 |
2100 |
1200 |
0.4 |
50 |
2500*1800*2200 |
2300 |
1500 |
0.4 |
50 |
2500*1860*2300 |
2600 |
1800 |
0.4 |
50 |
3000*2000*2300 |
4000 |
2000 |
0.4 |
50 |
3000*2000*2300 |
5000 |
2500 |
0.4 |
50 |
4000*2438*2500 |
6000 |
3000 |
0.4 |
50 |
6000*2438*2500 |
7000 |
Medium voltage | ||||
1000 |
6/10.5 |
50/60 |
3000*2438*2500 |
3500 |
1200 |
6/10.5 |
50/60 |
4000*2438*2500 |
3900 |
1500 |
6/10.5 |
50/60 |
4000*2438*2500 |
4500 |
1600 |
6/10.5 |
50/60 |
5000*2438*2500 |
5000 |
1800 |
6/10.5 |
50/60 |
5000*2438*2500 |
6500 |
2000 |
6/10.5 |
50/60 |
6000*2438*2500 |
7500 |
2200 |
6/10.5 |
50/60 |
6000*2438*2500 |
8000 |
2500 |
6/10.5 |
50/60 |
6000*2438*2500 |
10000 |
3000 |
6/10.5 |
50/60 |
7000*2438*2500 |
12000 |
4000 |
6/10.5 |
50/60 |
8000*2438*2500 |
14000 |
5000 |
6/10.5 |
50/60 |
9000*2438*2500 |
15000 |
6000 |
6/10.5 |
50/60 |
12000*2438*2500 |
16000 |
7000 |
6/10.5 |
50/60 |
12000*2438*2500 |
17000 |
8000 |
6/10.5 |
50/60 |
12000*2438*2500 |
18000 |
TRANSPORT AND INSTALL
The top four corners of the load bank are provided with lifting holes and the bottom four corners are provided with rollers to facilitate loading, transportation and mobile installation.
ELEVANT STANDARDS
The design, production and service of the system shall be in strict accordance with the requirements of quality management system (GB / T19001-2008) and refer to the following standards (some of which may not be suitable for practical application, and the final production scheme of the system shall be subject to the technical agreement agreed by both parties):
National standard
GB/T 2820.5-2009 Reciprocating internal combustion engine driven AC generator sets Part 5: generator sets
GB/T 13032-2010 Marine diesel generator set
GB/T 1029-2005 Test methods for three phase synchronous motors
GB 14711-2006 Safety requirements for small and medium rotating electrical machines
Military standard
GJB 5785-2006 General specification for military internal combustion generator set
GJB 235-1997 General specification for military AC mobile power station
GJB 1488-92 General test method for power supply of military internal combustion engine
HONORARY QUALIFICATION
Since its establishment, Rata has obtained 16 utility model patent certificates and 8 computer software copyright registration certificates, and has been recognized as a national high-tech enterprise.
http://www.cnloadbank.com/